Skip to main navigation Skip to search Skip to main content

Comparative sensitivity to cortical material heterogeneity and trabecular modeling in a geometrically diverse sample of human cranial finite element models

  • East Tennessee State University

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution

Abstract

Previous finite element (FE) studies have tested how regionally variable versus homogeneous cortical bone properties influence biomechanical performance, and others have evaluated the consequences of differences in trabecular modeling. However, nearly all these efforts have focused on modifying a single specimen, leaving open whether those findings hold across diverse morphologies. Here, we assess the sensitivity of cortical material assignment and trabecular modeling across a series of geometrically distinct human cranial FE models. We selected six crania at the extremes of shape variation, plus one near the sample centroid, based on a geometric morphometrics analysis of recent humans. Each model was analyzed under P3 and M2 biting. We first assigned regionally variable cortical properties and homogeneous trabecular properties. We then produced a second set with homogeneous cortical properties. From these, we generated two further variants: one replacing facial trabecular bone with solid cortical bone, and another removing trabecular bone entirely to create hollow regions. Muscle forces were scaled to model volume, except that hollow models received the same forces as their cortical solid counterparts. We found that homogenizing cortical bone consistently reduces strain relative to the original regionalized model, but only moderately so. Hollowing out trabecular bone had even smaller effects, surprisingly showing reduced strain at several sites. Treating trabecular bone as cortical bone produced large strain reductions, essentially overstiffening the face. The largest differences appear at the postorbital bar and infraorbital region. Our findings suggest that cortical homogeneity has a consistent, but moderate effect. The biggest sensitivity is to how trabecular bone is modeled. If computational cost is a concern, deleting trabecular bone is better than modeling it as cortical. Importantly, these trends were consistent across a wide range of morphologies, indicating that the biomechanics of cortical homogenization and trabecular simplification are broadly predictable and not strongly dependent on cranial shape.
Original languageAmerican English
Title of host publicationThe Anatomical Record
Pages87-88
Number of pages2
Volume309
DOIs
StatePublished - Sep 18 2026

Cite this